DRMCC Retrofit Package Products

  • Monitoring
  • Monitoring & Cooling Control
  • Monitoring, Cooling Control and OLTC Control
  • T3-2100
    Cooling Control & Essential Monitoring


    Base Model Includes:
    • Local display
    • Insulation Loss of Life Algorithms for both IEEE and IEC models
    • Dynamic Maximum Loading Calculations
    • SCADA Communication output for DNP or Modbus via serial or Ethernet.
    T3-2200
    Cooling Control & Expanded Monitoring


    Base Model Includes:
    • Local display
    • Insulation Loss of Life Algorithms for both IEEE and IEC models
    • Dynamic Maximum Loading Calculations
    • SCADA Communication output for DNP or Modbus via serial or Ethernet.
    T3-3200
    Cooling Control & Expanded Monitoring with LTC Monitoring

    Base Model Includes:
    • Local display
    • Insulation Loss of Life Algorithms for both IEEE and IEC models
    • Dynamic Maximum Loading Calculations
    • SCADA Communication output for DNP or Modbus via serial or Ethernet.
    T3-1100
    Essential Monitoring



    Base Model Includes:
    • Local display
    • Insulation Loss of Life Algorithms for both IEEE and IEC models
    • Dynamic Maximum Loading Calculations
    • SCADA Communication output for DNP or Modbus via serial or Ethernet.
    Monitored Values:
    • Top Oil Temperature
    • Ambient Temperature
    • Single Phase load monitoring
    • Calculated Winding Hot Spot Temperature
    • Fan Monitoring
    • Cooling Control Auto/Man
    • Low Oil Main Tank
    • Pressure Relief Device
    • Sudden Pressure Relay
    • Nitrogen Pressure High
    • Nitrogen Pressure Low
    • Nitrogen Cylinder Low
    Monitored Values:
    • Top Oil Temperature
    • Ambient Temperature
    • Single Phase load monitoring
    • Calculated Winding Hot Spot Temperature
    • Fan Monitoring
    • Cooling Control Auto/Man
    • Low Oil Main Tank
    • Pressure Relief Device
    • Sudden Pressure Relay
    • Nitrogen Pressure High
    • Nitrogen Pressure Low
    • Nitrogen Cylinder Low
    • LTC Temperature (Delta T Monitoring)
    • OLTC Tap Position
    • LTC Low Oil Level
    • LTC PRD
    Monitored Values:
    • Top Oil Temperature
    • Ambient Temperature
    • Single Phase load monitoring
    • Calculated Winding Hot Spot Temperature
    • Fan Monitoring
    • Cooling Control Auto/Man
    • Low Oil Main Tank
    • Pressure Relief Device
    • Sudden Pressure Relay
    • Nitrogen Pressure High
    • Nitrogen Pressure Low
    • Nitrogen Cylinder Low
    Monitored Values:
    • Top Oil Temperature
    • Ambient Temperature
    • Single Phase load monitoring
    • Calculated Winding Hot Spot Temperature
    • Fan Monitoring
    • Cooling Control Auto/Man
    • Low Oil Main Tank
    • Pressure Relief Device
    • Sudden Pressure Relay
    • Nitrogen Pressure High
    • Nitrogen Pressure Low
    • Nitrogen Cylinder Low
    • LTC Temperature (Delta T Monitoring)
    • OLTC Tap Position
    • LTC Low Oil Level
    • LTC PRD
    Control Functions:
    • Cooling Control
    Control Functions:
    • Cooling Control
    Control Functions:
    • Cooling Control
    Control Functions:
    • Cooling Control
    Included Sensors:
    • Top Oil Probe
    • Ambient temperature Sensor
    • Fixed core load CT
    • Fan Sensing CTs
    Included Sensors:
    • Top Oil Probe
    • Ambient temperature Sensor
    • Fixed core load CT
    • LTC temperature sensor
    • Fan Sensing CTs
    Included Sensors:
    • Top Oil Probe
    • Ambient temperature Sensor
    • 3 Phase Fixed core load CT assembly
    • Fan Sensing CTs
    Included Sensors:
    • Top Oil Probe
    • Ambient temperature Sensor
    • 3 Phase Fixed core load CT
    • LTC temperature sensor
    • Fan Sensing CTs
    Optional Items:
    • Other or additional alarm contact input signals
    • Other or additional analog values.
    • Remote User Interface Display (for installation in the control room)
    • Serial connection to DGA, moisture-in-oil, bushing monitoring or other IEDs or sensors.
    Optional Items:
    • Other or additional alarm contact input signals
    • Other or additional analog values.
    • Remote User Interface Display (for installation in the control room)
    • Serial connection to DGA, moisture-in-oil, bushing monitoring or other IEDs or sensors.
    Optional Items:
    • Other or additional alarm contact input signals
    • Other or additional analog values.
    • Remote User Interface Display (for installation in the control room)
    • Serial connection to DGA, moisture-in-oil, bushing monitoring or other IEDs or sensors.
    Optional Items:
    • Other or additional alarm contact input signals
    • Other or additional analog values.
    • Remote User Interface Display (for installation in the control room)
    • Serial connection to DGA, moisture-in-oil, bushing monitoring or other IEDs or sensors.